b'GENERAL INFORMATION The SuperVault MH is the first The SuperVault MH is the first tank to pass the SwRI 95-03 Multi-Hazard test, tank to pass the SwRI 95-03the toughest national test for aboveground fuel tanks. Most tanks are single- Multi-Hazard test, the toughest hazard rated which means they can withstand a hazard (fire, bullet, impact) national test for aboveground one time, but then have to be removed from service. The SuperVault MH has beenfuel tanks. Most tanks are single-tested for multiple exposure to fires and other hazards, plus an extended elementhazard rated which means they exposure test. This means that if the SuperVault MH experiences a hazard, it maycan withstand a hazard (fire, be re-certified and kept in service rather than having to be replaced. bullet, impact) one time, but then have to be removed from service.In addition to SwRI 95-03, the listing includes a four - hour fire rating. It meetsthe stringent safety requirements of Uniform Fire Code Appendix Standard A-II-F-1FEATURES(UFC 79-7), SwRI Test Procedure 93-01, NFPA 30/30A, and UL 2085 Protected Tank20 - Year Transferable Warrantyand Interstitial Communication Test. Light Weight, Easy to InstallThe SuperVault MH provides safe, aboveground storage, with the highestand Relocateinsulation value available in a lightweight concrete design. The unique designTrue Field Testable Secondary provides unsurpassed fire protection and ballistic resistance. Installation andContainmenthandling is much easier than tanks encased in heavy weight concrete. Since High Impact Resistancethe tanks are relatively lightweight, they can be shipped anywhere in the world.True 110 percent Secondary ContainmentSUPERVAULT MODELS Four - Hour Fire RatingBullet ResistanceOnly Tank Listed Reusable After a Hazard (subject to fire official inspection)Seismic Restraints Partof Every TankExternal Diking Not Requiredby UFCMH Series Cylindrical Tanks MH Series Rectangular TanksThe insulating concrete is protected from deterioration and damage by an additional outer steel tank. The MH Series is available in two styles, cylindricaland rectangular.MODELSThe ParkUSAs SuperVault present two models, these are dictated by the typeof configuration the containment tank may have.MH Series Cylindrical Tanks: Available from 250 gallons to 20,000 gallons, the cylindrical line of the MH Series offers two advantages to the fleet fueling operation: larger capacities and less wasted fuel in the bottom of the tank. For example, lets say a suction tube is cut 6 inches from the bottom of a fuel tank to avoid settling debris or water common with fuel storage. In a 12,000 gallon rectangular tank, the end user would have approximately 840 gallons of unusable fuel at 6 inches. At 6 inches in a 12,000 gallon cylindrical tank, the volume left is only 240 gallons. This means the owner of a 12,000 gallon SuperVault has 600 additional gallons, 71 percent more in the bottom 6 inches than larger rectangular ASTs.MH Series Rectangular Tanks: Rectangular SuperVaults are available from 250 gallons to 2,000 gallons.The advantages of rectangular designs are smaller footprints, less visual impact and simplicity in operating tank-top pumps and accessories.452'