b'LT ENGINEERINGCATALOG SIZINGThe oil/water separator is selected based on anticipateddistribution, particle rise, and other relevant inputflow rate (gpm) and type influent discharged through to make accurate performance predictions. This sizing the interceptor.technique assures a site-specific custom design forevery application.The flow rate can be estimated by summing up all the fixture units as listed in the plumbing code manual andFor example, if the given flow has a 50 GPM value,converting this into flow rate (gpm). Once flow rate isthe SOCMP needed would be a 500 gallons unit.established, ParkUSA uses a Mpak proprietary computer- Further design on plates efficiency can be also developed.modeling program, which utilizes Stokes Law, droplet size SOCMP Sizes AvailableMODEL NO STANDARD SIZENOMINAL FLOWINTERCEPTORNOMINAL OIL LENGTH X WIDTH RATE (GPM) VOLUME GAL CAPACITY GALSOCMP-500 7-10 X 4-4 50 500 250SOCMP-750 7-10 X 4-4 75 750 375SOCMP-1000 8-8 X 5-4 100 1,000 500SOCMP-1500 9-0 X 6-0 150 1,500 750SOCMP-2000 9-0 X 6-0 200 2,000 1,000SOCMP-3000 12-0 X 6-0 300 3,000 1,500SOCMP-4000 15-0 X 7-6 400 4,000 2,000SOCMP-5000 15-0 X 7-6 500 5,000 2,500SOCMP-6000 15-0 X 7-6 600 6,000 3,000SOCMP-7000 18-9 X 9-0 700 7,000 3,500SOCMP-8000 18-9 X 9-0 800 8,000 4,000SOCMP-9000 18-9 X 9-0 900 9,000 4,500SOCMP-10000 18-9 X 9-0 1,000 10,000 5,000SOCMP-12000 21-2 X 11-2 1,200 12,000 6,000SOCMP-15000 21-2 X 11-2 1,500 15,000 7,500Call for sizes not listed or specific project requirements 888-611-7275.316 INFO@PARKUSA.COM|888-611-7275|WWW.PARKUSA.COM'