b'STORMWATERCATALOGTesting of Park Environmental Equipment StormTrooper Interceptor _________________________________________________________________________________________________________ 4.6.1Test ConfigurationValve configurations are as follows: Valves Open:VC1, VC2, VR1, VR2 Valves Closed VD1, VD2, VL1, VL24.7Interceptor Model ST-06 - The Interceptor model ST-06 is a cylindrical design, 600 gallon capacity with the inlet & outlet on opposing ends of the interceptor. Thelocationoftheinlet/outletwillvaryaccordingtotheapplication,andan alternate location will be on the same side. This Interceptor will be tested at (3) different flow rates: 100, 150, & 200 gpm.4.7.1Test ConfigurationValve configurations are as follows: Valves Open:VC1, VC2, VD1, VD2 Valves Closed VR1, VR2, VL1, VL2 5.0Testing Procedures1.Each test will be conducted adding a mathematically calculated quantity of pollutants. Note the appropriate Data Chart and note the following the Group and Model Tested. Refer to Tables 2.A, 2.B, or 2.C 2.Energize Pump and adjust Control Valve to Flowrate (Q) gpm 3.Observe the Flow Meter and adjust as described in Section 4.3 4.Observe the Surge Tanks to verify water flow 5.Observe the Sample Port #A to verify water flow 6.Observe the Mixing Port to verify water flow 7.Observe the Control Manhole to verify water flow 8.Observe the Sample Port #B to verify water flow 9.Observe the Reserve Tank to verify water flow 10. Adjust the Control Manhole to permit bypass of the water IF the flow rate exceeds test (Q) gpm 11. Let the system run until determined stable at the constant Flowrate (Q) 12. Fill Mixing Port Hopper with pre-mixed, pre-measured, solids or oil 13. The test will start at when signaled. Open Mixing Port Valve #VMP to dose in pollutants per Section 4.3 14. Within 30 seconds of the start of the test, take one sample of water from Sample Port #A per Section 4.5.1 15. At the predetermined times, take a water sample from Sample Port #B per Section #4.7.1 16. Enter appropriate data in tables 2.A & 2.B 17. Observe Interceptor Sludge Chamber for any measurable solidsAt the end of each test, samples are to be labeled and stored in an ice cooler. Within24hours,thesampleswillbetakentothecertifiedlaboratorytobe analyzed. Repeat this test for the remainder of the procedures. - 12 - 8-14358 INFO@PARKUSA.COM|888-611-7275|WWW.PARKUSA.COM'