b'STORMWATERCATALOGParkUSA offers a wide variety of sensors and customizable control panels for our products.These vary in size and function to effectively address the needs of your project.SENSORSHigh Oil LevelOil interface float switches indicate high oil levels following excessive oil accumulation in the designated holding area of a product. Each switch is actuated using stainless steel floats with specific gravity of 0.92, allowing each float to rise to the open position in the presence of water while sinking to the closed position in the presence of oil. The conduit head may be mounted with the structure or onthe outside of the unit.Grease InterfaceGrease interface float switches are used to indicate high oil levels following excessive oil accumulation in the designated holding area of a product. Grease interface float switches have a protective membrane (grease shield) to avoid fouling of the float switch actuators. Each switch is actuated using stainless steel floats with specific gravity of 0.92, allowing each float to rise to the open position in the presence of water while sinking to the closed position in the presence of oil. The conduit head may be mounted with the structure or on the outside of the unit.Fluid LevelLevel indicator float switches are typically used to indicate that the fluid levels are above a set elevation. The sensors actuation level is set during installation and remains in the open position while fluids are below this established limit. Single Float SwitchFor a steel holding tank, the conduit head is mounted on the outside of the unit. Performance is dependent on tank design and mounting location. For concrete holding tanks and those with debris screens the conduit head is mounted at a high elevation inside the structure with a lead runningto the float switch apparatus and is typically usedto detect flow obstruction and fluid buildup.Dual Float SwitchFor a steel holding tank, the conduit head is mounted on the outside of the unit. Performance is dependent on tank design and mounting location.For concrete holding tanks and those with debris screens the conduit head is mounted at a high elevation inside the structure with a lead runningto the float switch apparatus. Performance is dependent on tank design and mounting location.Triple Float Switch For a steel holding tank, the conduit head is mounted on the outside of the unit. Performance is dependent on tank design and mounting location. Typical applications include fluid level rising and fluid level falling detection. 252 INFO@PARKUSA.COM|888-611-7275|WWW.PARKUSA.COMSensors'