Fire Department Connections - Model

Fire Department Connection Assemblies

The ParkUSA® BackFlo™ is a water cross connection prevention system designed to protect the public water supply from hazardous cross contamination. Measures the volume of water usage for residential, municipal, commercial, and industrial applications.

Our modern community water supply system is designed to ensure that water flows to properties and buildings under pressure. This community water network contains many users where there is a risk to public health if there is a cross-connection between the water supply and a contaminated source. A cross-connection can occur where there is a pressure drop in the water main. This pressure drop causes a vacuum and siphons of entrainment water from end-users into the public water supply. The backflow preventer is generally located inside the property line of the end-user’s facility and is installed in a concrete vault or on a concrete pad for protection and accessibility.

Municipalities around the country may require unique cross connection arrangements and specifications. Engineers rely on ParkUSA’s code knowledge and technical expertise to specify the right equipment.

Features
Dolor Sit Amet

  • Various models for different applications available
  • Completely pre-assembled for easy installation
  • Easy maintenance
  • Precast concrete vault or pad and insulated enclosure
  • Long-lasting and dependable service
  • Only certified equipment used for construction

Simply stated, a backflow preventer is a check valve device that’s installed on a potable piping system that allows water to flow in one direction, but never in the opposite direction. Its sole job is to prevent drinking water from being contaminated due to backflow. Backflow of water is caused by the pressure differential between the upstream (water main) and the downstream of the backflow device.

Water pressure can be affected when: 

  • There is a break in the water main.
  • Water is being pumped from the main water supply during a fire.
  • A customer is using water at a higher pressure than the pressure supplied.
  • The water outlet at the property is higher than the water main, causing constant back pressure.​
  • Heavy water use downstream reduces water pressure upstream.​

Additional Resources

File Preview ⬎

DDBP-AL-SL-Model

Double detector for fire service

BWV-1-Model

Backwater sewer valve

DDBPPF-AL-SL-Model

Detector check w/ post indic. valve & fire dept. connection

FDC-1-Model

Fire department connection

FDCPIV-1-Model

Fire dept. connection & post indicator valve

FMMH-1-Model

Force main discharge manhole

RPBPAE-1-Model

Above ground enclosed reduced pressure assembly

RPBPN-2-Model

Above gr. encl. N-pattern reduced pressure assembly

RPE-1-Model

Above ground enclosed reduced pressure assembly

VC-1-Model

Concrete vault with steel lid

VH-1-Model

Concrete vault with hatchway

VM-1-Model

Concrete vault with ring and cover

ARV-2-Model

Air relief valve

Flyer

BackFlo Flyer

BP34-2-Model

Double check assembly, 3/4" through 2"

BP-AL-SL-Model

Double check assembly, 3" through 10"